Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities
We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency
drift at 972 nm between two external cavity diode lasers independently
stabilized to two vertically mounted Fabry-Perot (FP) reference cavities.
Vertical FP reference cavities are suspended in mid-plane such that the
influence of vertical vibrations to the mirror separation is significantly
suppressed. This makes the setup virtually immune for vertical vibrations that
are more difficult to isolate than the horizontal vibrations. To compensate for
thermal drifts the FP spacers are made from Ultra-Low-Expansion (ULE) glass
which possesses a zero linear expansion coefficient. A new design using Peltier
elements in vacuum allows operation at an optimal temperature where the
quadratic temperature expansion of the ULE could be eliminated as well. The
measured linear drift of such ULE FP cavity of 63 mHz/s was due to material
aging and the residual frequency fluctuations were less than 40 Hz during 16
hours of measurement. Some part of the temperature-caused drift is attributed
to the thermal expansion of the mirror coatings. High-frequency thermal
fluctuations that cause vibrations of the mirror surfaces limit the stability
of a well designed reference cavity. By comparing two similar laser systems we
obtain an Allan instability of 2*10-15 between 0.1 and 10 s averaging time,
which is close to the theoretical thermal noise limit.Comment: submitted to Applied Physics
New Measurement of the 2S Hyperfine Interval in Atomic Hydrogen
An optical measurement of the 2S hyperfine interval in atomic hydrogen using
two-photon spectroscopy of the 1S-2S transition gives a value of 177 556
834.3(6.7) Hz. The uncertainty is
2.4 times smaller than achieved by our group in 2003 and more than 4 times
smaller than for any independent radio-frequency measurement. The specific
combination of the 2S and 1S hyperfine intervals predicted by QED theory
Hz is in good
agreement with the value of 48 923(54) Hz obtained from this experiment.Comment: 4 pages, 4 figure
Optical Clocks in Space
The performance of optical clocks has strongly progressed in recent years,
and accuracies and instabilities of 1 part in 10^18 are expected in the near
future. The operation of optical clocks in space provides new scientific and
technological opportunities. In particular, an earth-orbiting satellite
containing an ensemble of optical clocks would allow a precision measurement of
the gravitational redshift, navigation with improved precision, mapping of the
earth's gravitational potential by relativistic geodesy, and comparisons
between ground clocks.Comment: Proc. III International Conference on Particle and Fundamental
Physics in Space (SpacePart06), Beijing 19 - 21 April 2006, to appear in
Nucl. Phys.
Pathway to the PiezoElectronic Transduction Logic Device
The information age challenges computer technology to process an
exponentially increasing computational load on a limited energy budget - a
requirement that demands an exponential reduction in energy per operation. In
digital logic circuits, the switching energy of present FET devices is
intimately connected with the switching voltage, and can no longer be lowered
sufficiently, limiting the ability of current technology to address the
challenge. Quantum computing offers a leap forward in capability, but a clear
advantage requires algorithms presently developed for only a small set of
applications. Therefore, a new, general purpose, classical technology based on
a different paradigm is needed to meet the ever increasing demand for data
processing.Comment: in Nano Letters (2015
New Limits to the Drift of Fundamental Constants from Laboratory Measurements
We have remeasured the absolute - transition frequency in atomic hydrogen. A comparison with the result of the previous
measurement performed in 1999 sets a limit of Hz for the drift of
with respect to the ground state hyperfine splitting in Cs. Combining this result with the recently published
optical transition frequency in Hg against and a
microwave Rb and Cs clock comparison, we deduce separate limits
on yr and the
fractional time variation of the ratio of Rb and Cs nuclear magnetic moments
equal to
yr. The latter provides information on the temporal behavior of the
constant of strong interaction.Comment: 4 pages, 3 figures, LaTe
Determination of nutrient salts by automatic methods both in seawater and brackish water: the phosphate blank
9 páginas, 2 tablas, 2 figurasThe main inconvenience in determining nutrients in seawater by automatic methods is simply solved:
the preparation of a suitable blank which corrects the effect of the refractive index change on the recorded
signal. Two procedures are proposed, one physical (a simple equation to estimate the effect) and the other
chemical (removal of the dissolved phosphorus with ferric hydroxide).Support for this work came from CICYT (MAR88-0245 project) and
Conselleria de Pesca de la Xunta de GaliciaPeer reviewe
- …